Welcome to Zhonglian Industrial Global Portal! | 25+ Years Precision Extrusion | 100% Virgin Resins Guarantee
Global Direct Export Hotline: +86-138-0000-8888 | export@zhonglian-piping.com | Free Sample & RFQ
Zhonglian Industrial Logo

Technical Specifications & Design Manual

Comprehensive engineering reference for piping temperature-pressure derating, HDPE weight charts, and socket fusion welding parameters

1. PP-R Working Temperature & Pressure Derating Matrix (50-Year Design Life, Safety Factor C=1.5)

Due to polymer viscoelasticity under continuous heat, maximum permissible working pressures must be calculated according to ISO 15874 guidelines:

Operating Temp (°C) Derating Factor (fT) PN25 Pipe Permissible Pressure PN20 Pipe Permissible Pressure Application Guideline
20°C (Cold Water)1.002.50 MPa (25 bar)2.00 MPa (20 bar)Municipal water mains, residential cold riser
40°C (Warm Water)0.852.12 MPa (21.2 bar)1.70 MPa (17.0 bar)Solar & heat pump distribution circuits
60°C (Central Hot Water)0.681.70 MPa (17.0 bar)1.36 MPa (13.6 bar)Hotel & hospital circulation loops
70°C (Radiator Heating)0.541.35 MPa (13.5 bar)1.08 MPa (10.8 bar)District heating secondary loop
80°C (Industrial Peak)0.451.12 MPa (11.2 bar)0.90 MPa (9.0 bar)Process hot fluid transport
95°C (Fault Emergency)0.300.75 MPa (7.5 bar)0.60 MPa (6.0 bar)Boiler thermostat failure emergency limit

2. PP-R Standard Socket Fusion Heating, Insertion & Cooling Times (Tool Temp: 260°C ± 5°C)

Adherence to DVS 2207-11 standards is mandatory. Never rotate pipe or fitting during insertion.

Pipe Size (OD) Insertion Depth (mm) Heating Time (Seconds) Max Insertion Time (Seconds) Cooling Time (Minutes)
DN2014.0 mm5 s (Winter: 7 s)4 s2 min
DN2516.0 mm7 s (Winter: 9 s)4 s2 min
DN3218.0 mm8 s (Winter: 11 s)6 s4 min
DN4020.5 mm12 s (Winter: 15 s)6 s4 min
DN5023.5 mm18 s (Winter: 22 s)6 s5 min
DN6327.5 mm24 s (Winter: 30 s)8 s6 min