Welcome to Zhonglian Industrial Global Portal! | 25+ Years Precision Extrusion | 100% Virgin Resins Guarantee
Global Direct Export Hotline: +86-138-0000-8888 | export@zhonglian-piping.com | Free Sample & RFQ
Zhonglian Industrial Logo
Home > Products Center > Acoustic Gravity Drainage Systems > PVC-U Double-Wall Spiral Silence Drainage Pipe System
PVC-U Double-Wall Spiral Silence Drainage Pipe System
100% Virgin Resins
50-Year Design Life
✓ QA Inspected

Strict Wall Tolerance

✓ Free Samples

Fast Dispatch via DHL

✓ Direct Export

FOB / CIF Wholesale

ISO 3633 · ASTM D2665 Acoustic Gravity Drainage Systems CE & ISO Certified

PVC-U Double-Wall Spiral Silence Drainage Pipe System

Engineered with 6 internal continuous helical ribs that guide discharge water into a smooth rotational wall-adhering film. The central unimpeded air column eliminates hydraulic vacuum hammer, reducing drainage noise below 38 dB(A) in hospitals, hotels, and luxury towers.

Factory Direct Price: FOB / CIF Wholesale Inquiries (Direct from Manufacturer · Zero Middleman Markup)
• 48 Extrusion Lines / 7-14 Day Dispatch
Standard:ISO 3633 · ASTM D2665
Pressure Class:SN4 / SN8 Ring Stiffness
Size Range:DN50 ~ DN200 mm (2" - 8")
Working Temp:0°C ~ 65°C Gravity Drainage
Jointing Method:Flexible Rubber Ring Expansion / Solvent
Design Life:50-Year Warranty
✓ Free Project Material Takeoff Calculation · Full Batch Spectrometer Certificates · SGS / BV Pre-shipment Audit Support
OVERVIEW & ADVANTAGES

Product Engineering Highlights & Structural Design

01

100% Virgin Resins

Direct supply from Borealis, SABIC, and Sinopec. Absolutely zero recycled regrind or calcium fillers, guaranteeing maximum tensile elasticity.

02

Ultrasonic Wall Control

Automated KraussMaffei lines with 360° online ultrasonic thickness gauges ensure strict wall roundness and continuous dimensional precision.

03

Homogeneous Fusion

Thermal fusion melts molecular chains into a monolithic joint with zero mechanical weak points, eliminating risk of leakage for 50 years.

04

Ultra-Smooth Hydraulic Bore

Absolute roughness k=0.007mm minimizes flow friction and prevents scale deposition, boosting fluid energy efficiency over the entire lifecycle.

System Overview: Engineered with 6 internal continuous helical ribs that guide discharge water into a smooth rotational wall-adhering film. The central unimpeded air column eliminates hydraulic vacuum hammer, reducing drainage noise below 38 dB(A) in hospitals, hotels, and luxury towers.

Turnkey Engineering & Complete Fittings Compatibility:

  • Full Range of Molded Fittings: Equal tees, reducing tees, 90°/45° elbows, end caps, and custom manifold headers.
  • Premium HPb59-1 Brass Threaded Inserts: Precision CNC-machined dezincification-resistant brass with anti-rotation locking grooves to eliminate thermal creep leakage.
  • Drinking Water Hygiene Certification: Compliant with German DVGW, NSF/ANSI 61, and WRAS health requirements for human potable water.
TECHNICAL SPECIFICATIONS

Engineering Dimensions & Pressure Schedule

Standard metric and imperial dimensions in stock. Custom lengths, color striping, and OEM branding available upon request.

Nominal Size (OD) Wall Thickness (e) Spiral Rib Height Acoustic Noise Level Standard Length Recommended Applications
DN50 (2")2.0 mm1.2 mm≤ 35 dB(A)4m / barBalcony drain lines & floor drain branches
DN75 (2-1/2")2.3 mm1.5 mm≤ 36 dB(A)4m / barKitchen & sanitary fixture discharge stacks
DN110 (4")3.2 mm2.0 mm≤ 38 dB(A)4m / barHigh-rise residential core soil & waste stacks
DN160 (6")4.0 mm2.5 mm≤ 42 dB(A)4m / barPodium transfer collectors & roof stormwater
DN200 (8")4.9 mm3.0 mm≤ 45 dB(A)4m / barBasement suspended main drainage collectors
INSTALLATION GUIDE

Standard Operating Procedures & Jointing Protocol

STEP 1

Square Cut & Deburr

Cut pipe perpendicular to the axis with a dedicated rotary pipe cutter; clean burrs completely.

→
STEP 2

Mark Insertion Depth

Mark fusion depth using a depth gauge to avoid over-insertion and internal flow restriction.

→
STEP 3

Uniform Heat & Push

Heat simultaneously on 260°C die without rotation; join axially within the specified insertion window.

→
STEP 4

Cooling & Pressure Test

Allow natural cooling without stress; conduct hydrostatic pressure acceptance test at 1.5× design pressure.

FACTORY QUALITY ASSURANCE

CNAS Accredited Laboratory Inspection Standards

1. Hydrostatic Pressure Burst Test

Subjected to 1.5× nominal design stress at 95°C water bath for 1,000 hours with zero burst or leakage.

2. Charpy Impact Resistance at 0°C

2-hour freezing bath immersion followed by 2-meter heavy falling striker impact; zero shatter or micro-cracks.

3. Melt Mass-Flow Rate (MFR) Testing

Extruded samples verified against incoming raw material granules to ensure no thermal degradation occurred.

4. Longitudinal Reversion & Ring Stiffness

110°C thermal oven exposure testing verifies longitudinal deformation <2%; burial stiffness fully compliant.

Request Wholesale Export Pricing & Free Test Samples

Manufacturer-direct supply with expedited container booking. Tell us your required diameters, wall thickness, and destination port; our international engineering desk will provide a formal quotation within 15 minutes.

RECOMMENDED SYSTEMS

Related Thermoplastic Piping Lines